STOLLMANN GMBH TA-D Card Type ISDN TA Chip Set Unidentified Maximum Data Rate 64Kbps x 2 Data Bus External ISDN Modulation Protocol V.110, 1TR6, DSS1, X.30 [Image] CONNECTIONS Function Label Function Label Line out CN1 V.24 or X.21 port 1 CN4 DC power CN2 Reset button SW1 V.24 or X.21 port 2 CN3 Note: X.21 functionality is provided by an included adapter cable. USER CONFIGURABLE SETTINGS Setting Label Position Editor debug mode disabled J3 Open Editor debug mode enabled J3 Closed TA will use saved profile J4 Open TA will use default profile only J4 Closed Remote configuration enabled J6 Open Remote configuration disabled J6 Closed Port 1 is in V.24 mode J9 Open Port 1 is in X.21 mode J9 Closed Port 2 is in V.24 mode J10 Open Port 2 is in X.21 mode J10 Closed Port 1 is in DCE mode J13 Closed Port 1 is in DTE mode J13 Open Pin 25 of port 1 is not connected J13A Open Pin 25 of port 1 is +9V DC J13A Closed Port 2 is in DCE mode J14 Closed Port 2 is in DTE mode J14 Open Pin 25 of port 2 is not connected J14A Open Pin 25 of port 2 is +9V DC J14A Closed Pin 1 of port 1 is capacitive ground JN1 Open Pin 1 of port 1 is galvanic ground JN1 Closed Pin 1 of port 2 is capacitive ground JN2 Open Pin 1 of port 2 is galvanic ground JN2 Closed Factory configured - do not alter J5 Unidentified Factory configured - do not alter J7 Unidentified Factory configured - do not alter J8 Unidentified ISDN INTERFACE TYPE Setting J11 J12 S-interface Pins 1 & 2 closed Pins 1 & 2 closed U-interface Pins 2 & 3 closed Pins 2 & 3 closed LINE TYPE Setting J1 J2 Public ISDN Open Open ISDN PBX Closed Open ISDN PBX with LLC Open Closed DIAGNOSTIC LED(S) LED1 Status Condition On Power is on Off Power is off Blinking ISDN failed LED2 Status LED3 Status LED4 Status Condition Blinking Off Off TA is resetting Off Off Off Normal operation for channel 1 On Off Off ISDN connection established on channel 1 Alternating Alternating Off Hotline call repetition in progress on channel 1 Blinking Blinking Off Hotline call repetition error on channel 1 Blinking Off Off Hotline active without connection on channel 1 On Off Off Profile editor in use locally on channel 1 On On On Profile editor password being entered on channel 1 On Blinking Blinking Profile editor in use remotely on channel 1 Off Off On Unable to determine correct connection rate on channel 1 Off On Off Buffer has overflowed on channel 1 Alternating Blinking Alternating Checksum error has been detected on channel 1 LED5 Status LED6 Status LED7 Status Condition Blinking Off Off TA is resetting Off Off Off Normal operation for channel 2 On Off Off ISDN connection established on channel 2 Alternating Alternating Off Hotline call repetition in progress on channel 2 Blinking Blinking Off Hotline call repetition error on channel 2 Blinking Off Off Hotline active without connection on channel 2 On Off Off Profile editor in use locally on channel 2 On On On Profile editor password being entered on channel 2 On Blinking Blinking Profile editor in use remotely on channel 2 Off Off On Unable to determine correct connection rate on channel 2 Off On Off Buffer has overflowed on channel 2 Alternating Blinking Alternating Checksum error has been detected on channel 2 Proprietary Command Sets See document V1971 for a full command summary.